Docking Windows

Docking windows are windows containing commands and settings for specific construction aids or tasks. These are "docked" to the side of the HiCAD screen.

Docking windows can be shown/hidden under Settings > Docking window:

 

HiCAD supports docking windows as follows:

 

View

View structure of the current model drawing

Switch drawing

2-D-/3-D Part structure

Feature

HCM / HCM (2-D)

Properties

Graphics

Graphic preview of the active part
Part variables
Voreinstellung für die Darstellung von Linien, Flächen und Kanten

 

The following options are available for the processing of the windows:

You can change the size of the individual drawing windows by dragging the window frames to the required size (press and hold down LMB and drag).

The windows as well as individual tabs of the ICN can be hidden and redisplayed. For this you use the Settings > Docking window function.

A context menu provides further processing options for the windows. You activate the context menu by right-clicking on the required window.

 

 

Undocked windows can be freely moved with the mouse. Place the cursor on the caption bar of the window, press and hold down the LMB, drag the window to the required position and drop it by releasing the LMB.

In addition, you can define the window as a tab of the docking window: Use the symbol for this. If you want to revoke this assignment as tab, left-click on the corresponding tab and, while holding down the LMB, drag it to the required position.

 

Zooming contents

The contents of various docking windows can be enlarged or downsized dynamically by zooming. This is possible for the following docking windows:

To enlarge or downsize the contents of a single docking window, point the mouse cursor inside the window and turn the mouse wheel while holding down the CTRL key.

To enlarge or downsize the contents of all docking windows, turn the mouse wheel while holding down the CTRL and the SHIFT key.

The zoom of the active window can be reset by pressing the CTRL and middle mouse button simultaneously. To reset the zoom of all windows, press CTRL, SHIFT and the middle mouse button accordingly.


Docking window: Drawings

The Drawings docking window enables a quicker opening of HiCAD drawings. (.SZA). Simply select the required folder and double-click on the required file name.

If the window is not displayed, activate it via Settings > Docking windows.

This docking window can also be switched off permanently via the Window Registry. To do this, create in the Windows Registry at

HKEY_LOCAL_MACHINE\SOFTWARE\ISD Software und Systeme\HiCAD\3

a new DWORD value (32) Bit and assign the value 1 to it.

The docking window can then no longer be activated in HiCAD. If you want to re-enable the activation of the window, set the value in the Registry to 0.


Docking Window: Civil Engineering functions

Use this docking window to fit joints and connections, fasteners, stairs, railings, or other objects in Steel Engineering or Metal Engineering drawings.


Docking window: Panoramas

HiCAD offers the option to simulate environments. For this purpose a panorama is assigned to a Sheet or Model area. The surfaces of shaded models can then mirror this panorama, i.e. the environment.

This panorama can be used as background as well as for visualisation of environment mirroring.

 

Assign panorama

  1. In the Panoramas docking window, select the desired panorama.
  2. Activate the Use as background checkbox if you want to use the panorama as background of the sheet or model area. Please note that the corresponding area must not contain more than one view.
  3. Specify the Size factor and click Apply.

 

If the surfaces of shaded models are to mirror a panorama, i.e. the environment, activate the environment mirroring. To do this, use the Shaded view function under Shaded representation via Views > Representation > Shad... In the dialogue window, acitivate the checkbox Mirror panorama. Deactivate the checkbox to undo this effect.


Plugin windows

HiCAD supports the integration of freely definable plugins. If such plugins have been implemented in your system, they will be displayed in a docking window. Examples are the templates for planning grids in Metal Engineering or the Sheet Metal Cost Calculation tool.


Docking window: Simulation

You can use this tool to simulate and animate movements of parts in an assembly. You can also use HCM constraints to link the movements of individual parts to particular conditions. To be able to define or edit simulations, the Simulation docking window needs to be open.


Docking window: Part variables

In this docking window the Part variable of the active part and (if any) also those of the superordinate parts are displayed.

The symbols in front of the Part variables indicate the type of the variable.

 

Expand/collapse structure

The display of the Part variables can be expanded or collapsed by using the symbols and in the docking window above the Part structure. Use the icon to limit the display to the 1st and 2nd level of the part structure.

For opening/closing the variable display of each parts/assemblies use the symbols and .

 

Unused variables

With a click on the symbol you can mark all unused variables for deletion. The deletion will only be carried out after clicking on Apply all changes

 

CSV export

Click to create a CSV file that contains a list of all variables.

 

Use of variables

Clicking on opens the Use of variables dialogue window which which displays a list of where (and if) all variables for the selected part are used in the model drawing.

 

 

 

 

 

Context menu for variables and values/comments

With a click on the right-mouse button, context menus for variables as well as values/comments can be opened analogously. With these functions it is possible to

 

In order to change the value or comment of a variable, click on the respective field and enter the desired change. The variable will be marked with . Only if you click Save all changes, the change will be implemented.

Save all changes

The function Save all changes in the properties docking window saves the changes of the variable list:

The marks will be deleted subsequently.

By activating the function all delete markers will be removed.

Please also read the information in the Value Input (General Advice on Formulas and Variables) topic of the Feature Technology Help.


Exploded view

This docking window shows a log of an exploded view of a model drawing.

Exploded views can be edited subsequently via this log.

User Interface • PluginsSimulate EnvironmentsTextures