R+I-Schema > Lists
The List Generator in the P+ID module enables the creation of lists of symbol data contained in the P+ID as well as any linked part data in a wide range of different lists.
The BOM file *.SLI is a temporary file saved with the project to the *.RPA file.
The List function group on the P+ID tab contains the following functions:
Functions |
Description |
|
---|---|---|
|
Use this function to generate a new Bill of Materials(BOM). |
|
Pull-down menu List |
||
|
Executes the functions New list and New sheet in sequence. Some of the input masks are however suppressed during the process. |
|
|
This function enables you to create a number of graphical lists at the press of a button, no entries are expected. Graphical Lists are created for all list definitions files belonging to the list set file. |
|
|
This function updates all lists belonging to the current project for which a sheet and/or a file has been created. Lists inserted via the functions Insert in sheet and On new sheet are not updated. |
|
|
Use the dialogue box called with this function to create a new list definition. |
|
|
By editing the list set files you can specify which lists are to be created with the Lists from set function. |
|
|
This function enables you to display a BOM by opening a SLI file. The BOM is then displayed in the Report Manager. |
|
|
Inserts a graphical list into the active sheet. |
|
|
Generates a graphical list on one or several sheets, which are created specifically for the list. |
|
|
Deletes list output files. |
In older HiCAD versions, only symbols with part assignment appeared in the lists, Since version 1212.1, you can also create lists containing symbols with and without part assignment.
Please note:
Please expand the created BOM definitions accordingly, if required.
Since version 1212.1, the second digit of the attribute code will no longer be used for the determination of the maximum length of the transferred text. Generally, a maximum of 255 characters of the attribute content can be taken over.
If a dialogue text or an attribute text contains double quotation marks ("), the will be replaced by two single quotation marks (') in the BOM. This is necessary, because the Report Manager does not allow double quotation marks in the transferred character strings.
During BOM generation, temporary files with the extensions .ERG, .RFZ and .SRT. are created. These files are now no longer written into the folder of the active project, but into ...\TEMP folder.