Pre-Settings for Itemisation

In the Configuration Editor you can specify different settings for itemisation, namely, at


Settings for the Itemisation up to HiCAD 2017

The pre-settings for the old itemisation (up to HiCAD 2017) can be defined at Compatibility > Itemisation up to HiCAD 2017.

 

The settings specified here are the pre-settings for the dialogue window of the itemisation up to HiCAD 2017.

 

The parameter settings for Updating also apply to the new itemisation mode Standard itemisation since HiCAD 2018. Please read the information given at the bottom of this page!


Settings for itemisation

The settings for the Standard itemisation since HiCAD 2018 can be found at System settings > Itemisation.

 

Please note that the Itemisation up to HiCAD 2017 will end with HiCAD 2020. This means that the Itemisation up to HiCAD 2017 is no longer available from HiCAD 2021 onwards.

 

Switch to new standard itemisation

Use the Configuration Editor to define the procedure for starting the itemization in a model drawing that still uses the itemization up to HiCAD 2017. To do this, open the Configuration Editor and choose System settings > Itemisation > Switch to 'Standard itemisation used since HiCAD 2018'.

The following options are available here:

You then have the option of determining whether or not the itemization should be converted to the standard itemization. To Cancel the itemization function, use the same named option.

Here, however, you only have the possibility to change to the standard itemization with OK or to Cancel the itemization function.

The default setting is Optional.

 

Default settings

For the standard itemisation the parameter settings will be loaded from a Favourites file. By default, settings for Mechanical Engineering, Steel Engineering and Plant Engineering have been predefined. Which of these Favourites will be used depends on the settings specified in the HiCAD Parameter configuration dialogue window. You can also create your own Favourites files within the itemisation function and select them as defaults in the Configuration Editor.

The ISD default settings can not be overwritten by the user. These are locked for editing and marked with in both Manage favorites and the Configuration editor. In order to change and reuse these settings, they must be saved under a different name. In case of an update, the existing default settings can be prescribed by ISD and/or further settings may be added.

 

If no Favourites file has been selected, the following message will be displayed when you call the automatic itemisation function:

In this case, the settings must be specified via the functions Drawing > Itemisation/Detailing > Item. > ... with options or Drawing > Itemisation/Detailing > Item. > Change parameters.

Missing Favourites and/or adequate settings can lead to undesirable results.

Update item text

The new parameter Update item text set the time for updating item texts:

The setting After itemisation is useful if you work with large drawings and attributes from superordinate assemblies are used in the item texts. In this case, the setting After each change may have a negative effect on performance. Please note, however, that the setting After itemisationhas the disadvantage that it is not possible to recognize whether an item text is invalid.

 

Important:

The settings specified at Compatibility > Itemisation up to HiCAD 2017 > Updating also apply to the Standard itemisation!

If you want to use this mode, please remember the following:

Itemisation FunctionsThe "Drawing" Tab