Define Link
                 
            
            If a link has not been defined yet, you first need to define a suitable one:
- Select the HELiOS Desktop Define link function.
 - In the Designation field, enter a name for the new link, e.g. LINK_NEW.
 - Select for the source class as well as for the target class the Part entry.
 - Select the link type M:N.
 - End the function with OK.
 
The Part - Part link must be specified in the Bills of Materials tab of the Plant Engineering Settings dialogue.
Proceed as follows to specify this setting:
- Select Settings > Plant Engineering Settings, then activate the Bills of Materials tab.
 - Click the Select button next to the Link for accessory set input field.
 - The Find links window is displayed. If required, set some filter criteria and click Start search. The found data records are displayed.
 - Mark the data record LINK_NEW - Part-Part.
 - Click Apply.
 - Exit the Plant Engineering Settings window with OK.
 
                
            
Accessory Parts - Part Data Source: Database (PE) • Settings: Part Selection (PE) • Settings: Bills of Materials (PE)