Insert Bolted Flange Connection for Complete Pipeline

Plant Engineering > Part Tools > Exchange > Flange connection, bolted - Pipeline

Click the part of the pipeline into which you would like to insert the bolted flange connections.

First, the dialogue with general Settings for bolted connections will be displayed (if it has not been deactivated with the Suppress window checkbox). Here, especially the options for Level of detail and Geometry are of interest. In the Grip length area, you should always choose the Calculate option. The specified Fitting mode is not relevant here.

Specify the desired settings and confirm with OK.

If the required bolted flange connections have already been saved as referenced KRA files, and only one saved bolted flange connection exists for each insertion position, no further data input will be required and all bolted flange connections will be automatically inserted.

Otherwise, the required input data will be queried for the corresponding insertion position, as described in the Insert Individual Bolted Flange Connection topic.

 

The bolts will be aligned as follows:

Part Tools (PE)Plant Engineering Functions