Rules for the creation of individual Plant Engineering parts
Named isolated points
Designation |
Purpose |
Comment |
Position in coordinate system |
---|---|---|---|
! |
Fitting point |
Reference point placed on the centre line of a pipe during fitting |
in origin (0,0,0) |
2 |
Auxiliary point |
|
X < 0, Y = 0, Z = 0 |
Required attributes for entries into database or catalogue
The entering of attribute values and the part type selection should be performed using the PAA Editor.
Values need to be entered at least for the attributes shown below:
Possibility 1:
Attribute |
Description |
---|---|
BENENNUNG |
Designation of part |
NORMBEZEICHNUNG |
Standard designation of the part. An entry is mandatory, even if the part corresponds to no standard. |
NENNWEITE |
Nominal diameter |
D_AUSSEN |
Outer diameter of pipe (see DA in drawing) |
|
|
Additionally (only if the corresponding standard uses nominal diameters in inches): |
|
NPS_INCH |
Nominal diameter (inches) (e.g. 1 1/2‘', the '' consists of two '' characters) |
Possibility 2:
Attribute |
Description |
---|---|
BENENNUNG |
Designation of part |
NORMBEZEICHNUNG |
Standard designation of the part. An entry is mandatory, even if the part corresponds to no standard. |
D_AUSSEN |
Largest possible outer diameter of pipe that is still suitable for pipe clamp |
D2_AUSSEN |
Smallest possible outer diameter of pipe that is still suitable for pipe clamp |
NENNWEITE |
Nominal diameter matching D_AUSSEN |
Additionally (only if the corresponding standard uses nominal diameters in inches): |
|
NPS_INCH |
Nominal diameter (inches) (e.g. 1 1/2‘', the '' consists of two '' characters) |
For the insertion of a pipe clamp having these two outer diameter attributes the Also use Outer diameter 2 as search criterion for pipe clamps checkbox on the Part search tab of the Plant Engineering Settings dialogue must be active.
Creating Individual Parts: Procedure (PE)
© Copyright 1994-2018, ISD Software und Systeme GmbH |