Handling during loading and saving of a drawing containing externally referenced parts is determined by the update mode that has been set. This mode is defined in the Configuration Editor, at System settings > Referencing > Referenced 3-D parts On/Off.
Available modes are:
Please note that, when a drawing containing referenced parts is saved, the link to the folder in which the parts are stored is also saved! When loading the drawing later on, the parts will be searched for in this folder!
On, with save
Here, when saving a drawing, HiCAD checks to see whether the drawing contains referenced parts and which of these parts has been modified since the drawing was last saved. The names of the found parts and the reason for the update - e.g. feature for referenced basic parts - are then displayed in a selection window.
Body name |
Update |
T_Sachnummer (Article number) |
T_Benennung (Designation) |
---|---|---|---|
TESTREF* |
File version |
TESTREF |
|
If you also want the non-modified parts to be displayed in the list, activate the Also display non-modified parts
checkbox.
For each part mentioned in the list, you can now define whether or not you want the part to be saved in its current version. This applies irrespective of whether the drawing is saved via the Explorer or the HELiOS database.
Define the handling of the parts mentioned in the list and then click OK.
OFF
When the drawing is saved, referenced parts are not checked and hence also not automatically updated. This means that the corresponding KRA files remain unchanged even if the part has been modified in the drawing. However, the parts of the drawing continue to be referenced! This is, in principle, the same as the procedure for deactivating all checkboxes in the On, with save mode.
You can only update the corresponding KRA file by applying the Save referenced part function to the changed part of the drawing.
On, without save
Referenced parts are only checked when a drawing is loaded. The procedure for saving drawings is the same as in the OFF mode.
Example - Save drawing with referenced parts (3-D)
Please note that, when loading a drawing containing referenced parts, HiCAD searches for the parts in the folder in which they were stored when they were fitted.
On, with save
HiCAD checks here to see whether the drawing contains referenced parts and whether they differ from the corresponding KRA files. It also checks to see which of the parts have been modified since the drawing was last saved. The names of the found parts and the reason for the update are then displayed in a selection window.
Body name |
Update |
T_Article number |
T_Designation |
---|---|---|---|
Q1* |
File version |
Q1 |
|
Z1* |
File version |
Z1 |
|
K1* |
File version |
K3 |
|
Z3* |
None |
Z3 |
|
For each part mentioned in the list, you can now define whether or not you want the part to be updated in the drawing. This applies irrespective of whether the drawing is loaded via the Explorer or the HELiOS database. If the Before the Name checkbox is activated, the part is updated in the drawing. If the checkbox is deactivated, the part is not modified in the drawing.
Define the handling of the parts mentioned in the list and then click OK.
OFF
When the drawing is loaded, referenced parts are not checked and hence also not automatically updated. This means that the parts in the drawing may not match the corresponding KRA file. This is, in principle, the same as the procedure for deactivating the checkboxes in the On, with savemode.
If you want to update these parts subsequently, you can do this by changing the update mode or by re-installing the KRA file. You will then be able to update the parts in the drawing.
On, without save
When drawings are loaded, this mode is the same as the On, wiih save mode.