Plant Engineering > New > Pipe parts >Insert P+ID part

 

If the layout plan has been linked to a P+ID, or if your drawing contains referenced 3-D assemblies linked to P+IDs, you can also determine components via the corresponding P+ID symbol.

Layout plan <->P+ID link

If you want to process a Plant Engineering layout plan while the corresponding P+ID has been loaded, proceed as follows:

If you click OK in the dialogue box showing dialogue data, or if you click No because you do not want to see symbol data, you are returned to the layout plan, whereby the part is now ready for insertion. If the part is already inserted, HiCAD issues an appropriate message, and highlights the part.

If no part has been assigned to the symbol, HiCAD looks for a suitable part. This search is based on the part ID contained in the symbol data mask, (in the case of pipe parts, it is also possible to find parts via the pipe class assigned to the pipeline and the nominal diameter), as well as the symbol name (if the appropriate setting has been made in the P+ID). You can then select the required part in the result list that appears on your screen.

When you insert the part, its item number is automatically entered in the data mask of the corresponding symbol in the P+ID, i.e. the P+ID symbol is assigned to the part.

If a part for the selected symbol has already been inserted in the layout plan, HiCAD will display a corresponding message and the part will be highlighted in the drawing.

 

Referenced assembly <-> P+ID link

If the active pipeline does not belong to a referenced 3-D assembly, and one of the P+IDs linked to the assembly has been loaded, you have the option to determine parts via their corresponding P+ID symbol. Activate the corresponding pipeline beforehand. The further procedure is identical to that for the Layout plan <->P+ID link.

 

Please note:

 