Rules for the creation of Feature Variants for Plant Engineering parts
Position of connecting points and determination of insertion lengths for various connection types |
|||
---|---|---|---|
Connection for butt welding |
Flange connection |
Connecting nipple for |
Connecting socket for |
|
|
|
|
a = Insertion length dimension (e.g. L, L1 etc.) |
a = Insertion length dimension (e.g. L, L1 etc.) |
a = Insertion length dimension (e.g. L, L1 etc.) |
a = Insertion length dimension (e.g. L, L1 etc.) |
Named isolated points
Designation |
Purpose |
Comment |
Position in coordinate system |
---|---|---|---|
! |
Connecting point |
Fitting point |
In origin (0,0,0) |
2 |
Connecting point |
|
X = 0, Y = 0, Z > 0 |
Name |
Description |
Attribute (optional) |
---|---|---|
L |
Distance between point “!“ and “2“ |
LAENGE |
If the variables names given in the Name column are used, you do not need to assign any attributes to them via the Variant Editor. If different variables are required, you need to assign the attributes given in the Attribute column.
A variables name may consist of a maximum of 4 characters and must not contain any spaces or special characters.
VAA file
Use the Variant Editor to enter the suitable part type into the VAA file.
Then, use the Variant Editor to expand the VAA file in such a way that it contains values for the sizes specified here, and that the predefined attribute assignment is entered:
Parameter All dimensions must be specified in millimetres; |
Variable |
Assigned attribute |
---|---|---|
Nominal width, Connection “!“ and “2“ |
N |
NENNWEITE |
Length |
L |
LAENGE |
|
||
Additionally (only if the corresponding standard uses nominal diameters in inches): |
||
Nominal diameter (inches) , Connection “!“ and “2“ |
NI |
N_INCH |
Nominal diameters in inches need to be entered as decimal values as well (e.g. 1.5 for 1 1/2‘‘). |
||
|
||
These parameters are to be considered for all connection types except for flange connections. For connecting sockets they refer to the pipe to be inserted: |
||
Outer diameter, Connection “!“ and “2“ |
D |
D_AUSSEN |
Wall thickness, Connection “!“ and “2“ |
S |
WANDDICKE |
If required, the attribute LAENGE needs to be assigned to the length variables (see Variables names above).
Also in the Variant Editor, enter the values for the attributes which are to apply to all sub-types of the variant.
Values must be entered for at least the following attributes:
Attribute |
Description |
|||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
BENENNUNG |
Designation of the part |
|||||||||||||||||||
COMPONENT_TYPE |
Part type (always = Semi-finished material + Plant Engineering) for HELiOS database only |
|||||||||||||||||||
NORMBEZEICHNUNG |
Standard designation of the part (identical for all sub-types!) An entry is mandatory, even if the part corresponds to no standard. |
|||||||||||||||||||
BELIEBIG_TEILBAR |
Indicates whether the cutting to length of the pipe, is permissible. |
|||||||||||||||||||
LIEFERLAENGE |
Supplied length in m (!) |
|||||||||||||||||||
|
|
|||||||||||||||||||
ANSCHLUSSART
ANSCHLUSSART2 |
Connection type for connection “!“ and “2“ If you want both pipe ends to have the same connection type it will suffice to specify a value for the ANSCHLUSSART attribute. If you want the two pipe ends to have different connection types, the connection type for Connection 1 must be specified for the ANSCHLUSSART attribute, and the connection type for Connection 2 for the ANSCHLUSSART2 attribute. If you want to create a new feature variant of a straight pipe with different connection types, the part must be constructed in such a way that the value of the attribute ANSCHLUSSART is smaller than the value of the attribute ANSCHLUSSART2. Example: Let us assume that you require a pipe that can be butt-welded at one end, and has a screwed socket at the other end. The connection type for butt-welded connections is 10000, the one for screwed sockets is 32000. This means that Connection 1 (Point designation "!") is required for the welded connection (ANSCHLUSSART = 10000) and Connection 2 (point designation "2") is required for the screwed connection (ANSCHLUSSART2 = 32000). |
|||||||||||||||||||
Possible values of the attribute ANSCHLUSSART (CONNECTION_TYPE) and ANSCHLUSSART2 (CONNECTION_TYPE2):
The last character (x) provides information about the meaning of the supplement: 0 =No supplement 2 = The supplement consists of connection number, part type, ID, and standard of the part to be connected The prefixed connection number indicates the connection with which the auxiliary part is to be attached to the current connection.
|
Handling of nominal diameters in inches in the HELiOS database:
During part data synchronization, nominal diameters in inches will be taken over to the attributes N_INCH, N2_INCH and N3_. The usual character strings for indication of the diameter in inches (e.g. 1 1/2‘‘ instead of 1.5) will be auto-generated in the database for the attributes NPS_INCH, NPS2_INCH und NPS3_INCH.
Related Topics
Rules for the Creation of User-Defined Parts (PE)
Version 2102 - HiCAD Plant Engineering | Date: 15/11/2016 | © Copyright 1994-2016, ISD Software und Systeme GmbH |