Variant for Part Type: Pipe Clamp
            
            Rules for the creation of Feature Variants for Plant Engineering parts
                
            
Named isolated points
| 
                             Designation  | 
                        
                             Purpose  | 
                        
                             Comment  | 
                        
                             Position in coordinate system  | 
                    
|---|---|---|---|
| 
                         !  | 
                    
                         Fitting point  | 
                    
                         Reference point placed on the centre line of a pipe during fitting  | 
                    
                         in origin (0,0,0)  | 
                
| 
                         2  | 
                    
                         Auxiliary point  | 
                    
                         
  | 
                    
                         X < 0, Y = 0, Z = 0  | 
                
VAA file
Use the Variant Editor to enter the suitable part type into the VAA file.
Then, use the Variant Editor to expand the VAA file in such a way that it contains values for the sizes shown below, and that the predefined attribute assignment is entered.
Possibility 1:
| 
                             Parameter  All dimensions must be specified in millimetres;               | 
                        
                             Variable   | 
                        
                             Assigned attribute   | 
                    
|---|---|---|
| 
                         These parameters apply to pipes which fit into the clamps  | 
                ||
| 
                         Nominal diameter  | 
                    
                         N  | 
                    
                         NENNWEITE  | 
                
| 
                         Outer diameter  | 
                    
                         DA  | 
                    
                         D_AUSSEN  | 
                
| 
                         
  | 
                ||
| 
                         Additionally (only if the corresponding standard uses nominal diameters in inches):  | 
                ||
| 
                         Nominal diameter (inches)  | 
                    
                         NI  | 
                    
                         N_INCH  | 
                
| 
                         Nominal diameters in inches need to be entered as decimal values as well (e.g. 1.5 for 1 1/2‘‘).  | 
                ||
Possibility 2:
| 
                             Parameter  All dimensions must be specified in millimetres;               | 
                        
                             Variable   | 
                        
                             Assigned attribute   | 
                    
|---|---|---|
| 
                         These parameters apply to pipes which fit into the clamps  | 
                ||
| 
                         Outer diameter  | 
                    DA | D_AUSSEN | 
| Outer diameter 2 Smallest possible outer diameter of pipe that is still suitable for pipe clamp  | 
                    D2 | D2_AUSSEN | 
| 
                         Nominal diameter  | 
                    
                         N  | 
                    
                         NENNWEITE  | 
                
| 
                         
  | 
                ||
| 
                         Additionally (only if the corresponding standard uses nominal diameters in inches):  | 
                ||
| 
                         Nominal diameter (inches)  | 
                    
                         NI  | 
                    
                         N_INCH  | 
                
| 
                         Nominal diameters in inches need to be entered as decimal values as well (e.g. 1.5 for 1 1/2‘‘).  | 
                ||
For variant synchronization you also need to enter the values for the attributes which are to apply to all sub-types of the variant.
Values must be entered for at least the following attributes:
| 
                             Attribute  | 
                        
                             Description  | 
                    
|---|---|
| 
                         BENENNUNG (DESIGNATION)  | 
                    
                         Designation of the part  | 
                
| 
                         COMPONENT_TYPE  | 
                    
                         Part type (always = Semi-finished material + Plant Engineering) for HELiOS database only  | 
                
| 
                         NORMBEZEICHNUNG (STANDARD_DESIGNATION  | 
                    
                         Standard designation of the part (identical for all sub-types!) An entry is mandatory, even if the part corresponds to no standard.  | 
                
                
                 Handling of nominal diameters in inches in the HELiOS database:
            
During part data synchronization, nominal diameters in inches will be taken over to the attributes N_INCH, N2_INCH and N3_. The usual character strings for indication of the diameter in inches (e.g. 1 1/2‘‘ instead of 1.5) will be auto-generated in the database for the attributes NPS_INCH, NPS2_INCH und NPS3_INCH.
                
 For the insertion of a pipe clamp having these two outer diameter attributes the Also use Outer diameter 2 as search criterion for pipe clamps checkbox on the Part search tab of the Plant Engineering Settings dialogue must be active. 
                
            