SDNF Interface
The international SDNF Interface (Steel Detailing Neutral File) enables you to import and export Steel Engineering drawings.
Load SDNF file
Drawing > New/Open > Open > SDNF
To import a file via the SDNF interface, you need to
- Activate the function.
- Choose the required SDNF file (File extension .DAT) and click Open to confirm. The SDNF Interface window is displayed. It offers the following setting options:
- Show conversion log: Any errors occurring during data transfer are logged to the conversion log , e.g. a listing of beams and profiles that are not recognised by the system. If the log should be shown after data export, activate the check box. A detailed listing of any errors that may appear in the protocol can be called by double clicking the appropriate entry
- Write log file: Details of the conversion log are written to a log file. If you want to create a log file (with the file extension .LOG), select the appropriate check box.
- Inner plate contours: Select this check box if you want to transfer inner contours, e.g. holes. In the field below, you can specify whether holes up to a specific size should be ignored.
- After selecting all required options, select OK to exit the SDNF Interface window.
Please note:
-
Beams and profiles that are not recognised by HiCAD are inserted in the drawing as bar elements.
-
When importing steel engineering plates, S235JRG2 will be used as the default material for the plates.
Save SDNF file
Drawing > Save/Print... > Save as > Further ... > SDNF
To export a file via the SDNF interface you need to:
- Activate the function. The standard dialogue box is opened, this enabling you to save the file.
- Select a path and enter a name for the export file. The file will be saved with the file extension .DAT.
- Click the Save button. The SDNF interface dialogue window is displayed.
- When you have selected all required options, close the dialogue window with OK.