Variant for Part Type: Pipe Clamp

Rules for the creation of Feature Variants for Plant Engineering parts

 

Named isolated points

 

VAA file

Use the Variant Editor to enter the suitable part type into the VAA file.

Then, use the Variant Editor to expand the VAA file in such a way that it contains values for the sizes shown below, and that the predefined attribute assignment is entered.

Possibility 1:

 

Possibility 2:

Outer diameter
Largest possible outer diameter of pipe that is still suitable for pipe clamp

DA D_AUSSEN
Outer diameter 2
Smallest possible outer diameter of pipe that is still suitable for pipe clamp
D2 D2_AUSSEN

 

For variant synchronization you also need to enter the values for the attributes which are to apply to all sub-types of the variant.

Values must be entered for at least the following attributes:

 

Handling of nominal diameters in inches in the HELiOS database:

During part data synchronization, nominal diameters in inches will be taken over to the attributes N_INCH, N2_INCH and N3_. The usual character strings for indication of the diameter in inches (e.g. 1 1/2‘‘ instead of 1.5) will be auto-generated in the database for the attributes NPS_INCH, NPS2_INCH und NPS3_INCH.

 

For the insertion of a pipe clamp having these two outer diameter attributes the Also use Outer diameter 2 as search criterion for pipe clamps checkbox on the Part search tab of the Plant Engineering Settings dialogue must be active.

Rules for the Creation of User-Defined Parts (PE)