Part Type: T-Piece

Rules for the creation of individual Plant Engineering parts

 

a = Insertion length dimension
(e.g. L, L1 etc.)
a = Insertion length dimension
(e.g. L, L1 etc.)
a = Insertion length dimension
(e.g. L, L1 etc.)
a = Insertion length dimension
(e.g. L, L1 etc.)

 

Named isolated points

 

Required attributes for entries into database or catalogue

The entering of attribute values and the part type selection should be performed using the PAA Editor.

Values need to be entered for at least the following attributes:

BENENNUNG

Designation of part

NORMBEZEICHNUNG

Standard designation of the part.

 

 

NENNWEITE

Nominal diameter, Connection “!“ and “2“

NENNWEITE3

Nominal diameter, Connection “3“

 

 

Additionally (only if the corresponding standard uses nominal diameters in inches):

NPS_INCH

Nominal diameter (inches) (e.g. 1 1/2‘', the '' consists of two '' characters), Connection “!“ and “2“

NPS3_INCH

Nominal diameter (inches), Connection “3“

ANSCHLUSSART

Connection type, Connection “!“ and “2“

ANSCHLUSSART3

Connection type, Connection “3“

 

 

These parameters are to be considered for all connection types except for flange connections. For connecting sockets they refer to the pipe to be inserted:

D_AUSSEN

Outer diameter, Connection “!“ and “2“

D3_AUSSEN

Outer diameter, Connection “3“

WANDDICKE

Wall thickness, Connection “!“

WANDDICKE3

Wall thickness, Connection “3“

Possible values of the attribute ANSCHLUSSART (CONNECTION_TYPE):

1000x

Butt-welded

Provide auxiliary part when fitting part

If appropriately preset in the ANSCHLUSSART (CONNECTION_TYPE) attribute for a connection, the part will provide and connect an auxiliary part of the standard specified in the attribute for the connection when being fitted. For example, if the part has a flange connection and the corresponding counter-flange is required, the content of the ANSCHLUSSART (CONNECTION_TYPE) attribute could look as follows:

20002 1 5100010 EN 1092-1/11/A/PN 40

EN 1092-1/11/A/PN 40 is the standard designation with which the flange is to be entered into the database.

2000x

Flange connection

2100x

Flange with groove connection

2200x

Flange with notch connection

2040x

Flange connection of a part that is not a flange itself. The part has a loose flange that is modelled as a sub-part and has no own article master attached to this connection.

3100x

Screwed, nipple

3200x

Screwed, socket

4100x

Plugged, nipple

4200x

Plugged, socket

5100x

Socket-welded, nipple

5200x

Socket-welded, socket

The last character (x) provides information about the meaning of the supplement:

0 =No supplement

2 = The supplement consists of connection number, part type, ID, and standard of the part to be connected

The prefixed connection number indicates the connection with which the auxiliary part is to be attached to the current connection.

 

Please also read the information given in the paragraphs Connection type ID with priority information and Connection type ID - List of part standards.

Creating Individual Parts: Procedure (PE)