Representation of Beams

Beams can be represented both in simplified form and exactly. The simplified representation does not, for example, display the radii of beams. Furthermore, you can also define whether you want beam annotations, axes and their end points as well as tracing lines of beams to be represented. This allows you, for example, to show and hide beam annotations separately in the workshop drawing and in the 3-D model.

Representation options (from left to right):
exact - simplified - only axes - beam with axes (1) and tracing lines

There are various options for defining the representation type of beams:

 

Changing the representation type via feature log

You can also use the feature log to change the representation type – by double-clicking Representation. In the window that is displayed, activate the desired option field and choose OK to exit the window.

Also available here is the Enter formula option, which you can use to assign a variable to the representation type. An example of a typical use case would be, for example, a beam with bores which you do not want to be visible in the simplified representation. Proceed as follows:

  1. Double-click Representation in the feature log entry for the beam.
  2. Choose the Enter formula option and enter a variable name, e.g. EXA for exact representation.
  3. Confirm the value 0.
  4. Double-click Constraint in the feature entry of the bore.
  5. Enter the variable name EXA.

The bores are then immediately hidden. If you then choose the Variables of the feature function and assign 1 to the variable EXA,  the exact representation is activated – with the bores.

Please note:


Representation types for staircases and railings

For staircases and railings created with the Staircase and Railing Configurator the representation type that has been pre-set in the model drawing will be used. The ISD default setting is Simplified.

If a drawing contains parts with different representation types, e.g. simplified staircases/railings that were inserted via the Configurators and, at the same time, Steel Engineering objects with exact representation, the representation type will be converted accordingly, on the basis of the identical search, when the drawing is itemized. HiCAD will display the following message:

In some cases, the conversion may fail after clicking Yes:

There are two possibilities how to solve this problem:

 

Important:
These solution possibilities will only be successful if the staircases/railings are still functional, that is, no parts of the staircase/the railing must have been deleted or broken up. Otherwise, all profiles of the staircase/the railing must be broken up until they appear as individual features in the ICN.e.g..