Project: HiCAD Interfaces

Working with several layouts (DXF/DWG interface)

If a DXF-file contains several LAYOUTs, these can be read one after another, depending on the value of the LAYOU parameter in sys\ACADHCAD.DAT .

Another option is that the model area will no longer be entered invisibly (on level=0) so that the drawing is not enlarged unnecessarily.

ACADHCAD.DAT: LAYOU ->

No layout query without model area transfer

No layout query with model area transfer

Layout query:

 

Without model area transfer

 

With model area transfer

 

Query only if 2 or more layouts

 

Query, even if only 1 layout to transfer the model area

The active layout/model will be transferred when the setting is LAYOU -1 or 0 (-1 corresponds to the proceedings up to version 1211.2)

If the settings are LAYOU 1 or 2, the number of the layout to be transferred will be queried if there are 2 or more layouts (1 is the active layout).

The model area can be transferred with 0.

The name of the transferred layout is recorded in the TEMP\ACADHCAD.PAR file.

Default -> LAYOU=1

Only the active layout will be transferred in list processing.

Load DXF/DWG File2-D Interfaces

© Copyright 1994-2019, ISD Software und Systeme GmbH
Version 2402 - HiCAD Interfaces
Date: 06/10/2019