Project: HiCAD Plant Engineering
Rules for the creation of Feature Variants for Plant Engineering parts
            
        
Named isolated points
| 
                         Designation  | 
                    
                         Purpose  | 
                    
                         Comment  | 
                    
                         Position in coordinate system  | 
                
|---|---|---|---|
| 
                     !  | 
                
                     Fitting point  | 
                
                     Reference point placed on the centre line of a pipe during fitting  | 
                
                     in origin (0,0,0)  | 
            
| 
                     2  | 
                
                     Auxiliary point  | 
                
                     
  | 
                
                     X < 0, Y = 0, Z = 0  | 
            
VAA file
Use the Variant Editor to enter the suitable part type into the VAA file.
Then, use the Variant Editor to expand the VAA file in such a way that it contains values for the sizes shown below, and that the predefined attribute assignment is entered.
Possibility 1:
| 
                         Parameter  All dimensions must be specified in millimetres;               | 
                    
                         Variable   | 
                    
                         Assigned attribute   | 
                
|---|---|---|
| 
                     These parameters apply to pipes which fit into the clamps  | 
            ||
| 
                     Nominal diameter  | 
                
                     N  | 
                
                     NENNWEITE  | 
            
| 
                     Outer diameter  | 
                
                     DA  | 
                
                     D_AUSSEN  | 
            
| 
                     
  | 
            ||
| 
                     Additionally (only if the corresponding standard uses nominal diameters in inches):  | 
            ||
| 
                     Nominal diameter (inches)  | 
                
                     NI  | 
                
                     N_INCH  | 
            
| 
                     Nominal diameters in inches need to be entered as decimal values as well (e.g. 1.5 for 1 1/2‘‘).  | 
            ||
Possibility 2:
| 
                         Parameter  All dimensions must be specified in millimetres;               | 
                    
                         Variable   | 
                    
                         Assigned attribute   | 
                
|---|---|---|
| 
                     These parameters apply to pipes which fit into the clamps  | 
            ||
| 
                     Outer diameter  | 
                DA | D_AUSSEN | 
| Outer diameter 2 Smallest possible outer diameter of pipe that is still suitable for pipe clamp  | 
                D2 | D2_AUSSEN | 
| 
                     Nominal diameter  | 
                
                     N  | 
                
                     NENNWEITE  | 
            
| 
                     
  | 
            ||
| 
                     Additionally (only if the corresponding standard uses nominal diameters in inches):  | 
            ||
| 
                     Nominal diameter (inches)  | 
                
                     NI  | 
                
                     N_INCH  | 
            
| 
                     Nominal diameters in inches need to be entered as decimal values as well (e.g. 1.5 for 1 1/2‘‘).  | 
            ||
For variant synchronization you also need to enter the values for the attributes which are to apply to all sub-types of the variant.
Values must be entered for at least the following attributes:
| 
                         Attribute  | 
                    
                         Description  | 
                
|---|---|
| 
                     BENENNUNG (DESIGNATION)  | 
                
                     Designation of the part  | 
            
| 
                     COMPONENT_TYPE  | 
                
                     Part type (always = Semi-finished material + Plant Engineering) for HELiOS database only  | 
            
| 
                     NORMBEZEICHNUNG (STANDARD_DESIGNATION  | 
                
                     Standard designation of the part (identical for all sub-types!) An entry is mandatory, even if the part corresponds to no standard.  | 
            
            
 Handling of nominal diameters in inches in the HELiOS database:
        
During part data synchronization, nominal diameters in inches will be taken over to the attributes N_INCH, N2_INCH and N3_. The usual character strings for indication of the diameter in inches (e.g. 1 1/2‘‘ instead of 1.5) will be auto-generated in the database for the attributes NPS_INCH, NPS2_INCH und NPS3_INCH.
            
 For the insertion of a pipe clamp having these two outer diameter attributes the Also use Outer diameter 2 as search criterion for pipe clamps checkbox on the Part search tab of the Plant Engineering Settings dialogue must be active. 
            
        
Rules for the Creation of User-Defined Parts (PE)
| 
                             
								© Copyright 1994-2019, ISD Software und Systeme GmbH  |