Project: HiCAD Plant Engineering
Part data synchronisation via command line should only be performed by experienced users!
You can also start the part data synchronisation via the Windows command line. For this you use the program
in the HiCAD subdirectory EXE.
After starting the program the Part data AutoSync window will be displayed. Please note that the Plant Engineering mode checkbox is active here. This option needs to be set for the part data synchronisation of Plant Engineering variants!
The control of the program via command line is useful for the definition of automated processes.
If the program PartDataAutoSync.exe is started via parameters from the command line, it depends on the parameter specification whether the Plant Engineering mode checkbox in the Part data AutoSync dialogue will be active or inactive.
PartDataAutoSync.exe /g
PartDataAutoSync.exe /p "c:\hicad\szenen\Test Datei 1.vaa"
or
PartDataAutoSync.exe /p c:\hicad\szenen\Test Datei 1.vaa
PartDataAutoSync.exe /d B00RZRY3XHNH0U00003JBR 0
The file must be located in the directory specified via HELiOS, or in the Vault Server.
PartDataAutoSync.exe /M
PartDataAutoSync.exe /F "Test Datei 1.vaa"
or
PartDataAutoSync.exe /F Test Datei 1.vaa
The file must be located in the directory specified by the file group ID '6' (e.g.: "c:\hicad\PlantParts").
PartDataAutoSync.exe /D B00RZRY3XHNH0U00003JBR 0
The file must be located in the directory specified by the file group ID '6' (z.B: "c:\hicad\PlantParts"), or in the Vault Server.
PartDataAutoSync.exe /L "List File 1.lst"
or
PartDataAutoSync.exe /L List File 1.lst
The file must be located in the directory specified by the file group ID '6' (z.B: "c:\hicad\PlantParts").
PartDataAutoSync.exe /I
Please note:
If you use the PartDataAutoSync.exe tool for part data synchronization with the HELiOS database, you can check whether the part type ID of a VAA or PAA file has changed. If this is the case, the classification of the article masters in HELiOS will be adjusted accordingly.
Part Data Tools (PE) • Plant Engineering Functions • Part Data Synchronisation with HELiOS Database
© Copyright 1994-2019, ISD Software und Systeme GmbH |