Straight Stairs - Parameters (3-D SE)
            
        
         "Civil Engineering" docking window" > Steel Engineering > Stairs+Railings > Stairs              
        You use the stair parameters on the Straight stairs 
 tab to define 
        
            - the 
 size of the stair start and stair end and the height of the unfinished floor, 
 
 
            - the 
 stringer type for the first and last steps,
 
            - the 
 stringer and step type,
 
            - the 
 distances between stringers and steps and the nose overhang as well as
 
            - the 
 number of rises.
 
        
        
            
        
        (1) Height above datum for stair start, (2) Height above 
 datum for stair end, (3) Height above datum for unfinished floor, (4) 
 Stringer beam height, (5) A1 stringer step upper edge, (6) A2 stringer 
 step upper edge, (7) A3 stringer step upper edge, (8) U1 nose overhang, 
 (9) Unfinished floor
        
        
            - Height 
 above datum
                
Enter the values for the stair start and stair end. If you want to use a specific floor structure for which the unfinished floor needs to be taken into account, enter this value as well. The values for the stair start and stair end determine the flight length. This is the dimension of first 
 step front edge to last step 
 front edge 
        
        
            - Stringers 
 for stair start / end
                
You choose the stringer type for the stair start and the stair end. Simply click the relevant symbol. If the Without 
 stairwell option is activated on the Settings: 
 Straight stairs tab, you can specify the size of the first/last 
 step in the Length field. 
        
        
            
        
        
            - Stringer 
 type, Step type
                
The stringer is the component of a staircase that bears the steps and 
 bounds the run to the side. The stringer type 
 allows you to choose between a U-beam and broad flat steel. You then define 
 the dimensions of the stringer via the selection list which you activate 
 by clicking the button on the right. You choose the step type and the 
 size of the step in the same way. 
        
        
            - Distances 
 and Nose overhang
                
In this window pane, you define the distances between stringers and 
 steps as well as the nose overhang. 
            - A1 
Perpendicular distance from the floor to the upper edge of the stringer. 
            - A2 
Direct distance from the upper edge of a step to the upper stringer 
 border. 
            - A3 
Perpendicular distance from the floor to the upper edge of the stringer. 
            - U1, W 
The stairs can either be generated by specifying the nose overhang U1 
 or the rise angle W. Activate the desired parameter and enter the value.
The nose overhang is the horizontal dimension by which the front edge of 
 a step protrudes over the width of the tread of the step below. It should 
 be at least 3 cm. The rise angle results from the step width, the number 
 of rises and the staircase height.
If you specify the rise angle W, the nose overhang results from the step 
 width, number of rises and the staircase height. 
            - Number 
 of rises
                
This value defines the number of rises. It is only evaluated if the 
 Rise data acc. to standard checkbox on the 
 Settings: Straight stairs tab is inactive. 
 If you enter 0 or 1 (no steps), the number of rises which comes closest 
 to the mean of the step rule (2r+t=620) is automatically determined in 
 the Rise variants dialogue window  
        
        
        
        
            
        
        Straight Stairs 
 (3-D SE) • Sketch (3-D) 
 • Stairs and Railings (3-D SE) 
        
            
                
                
                
                    
                        | 
                             
								© Copyright 1994-2018, ISD Software und Systeme GmbH 								Version 2302 - HiCAD Steel Engineering 								Date: 28/09/2018 
                         | 
                        
                             
								> Feedback on this topic 
                         |