Pipe Parts: Reducers (PE)

Plant Engineering > New > Pipe parts > Reducer

On condition that

the following functions are available for an interactive fitting of one or several reducers:

Automatic reducer connection

Connect all required reducers to one part automatically

Connect all required reducers for the complete active pipeline automatically

If the symbol appears next to a function, this function is not available.

 

Concentric reducers allow the creation of branchings by means of saddle connections or pipes with smaller diameters, via cylindrical sections ending in a connecting surface. Click here for further information.


Automatic reducer connection

Plant Engineering > New > Pipe parts > Reducer > Connect automatically

Identify the connecting point for the reducer first.

The nominal diameter of the part connection and the nominal diameter of the pipeline, respectively guideline c-edge, will automatically be used as search criteria for the reducer. The reducer will be connected in the correct direction automatically.

Example:

(1) DN50, (2) specification for pipeline DN100


Connect all required reducers to one part automatically

Plant Engineering > New > Pipe parts > Reducer > Connect 2 reducers

First identify the part to which you want to connect the reducers.

The nominal diameter of the individual part connection and the nominal diameter of the pipeline, respectively guideline c-edge, will automatically be used as search criteria for the reducer. The reducer will be connected in the correct direction automatically. If the selected part has flange connections, and if the appropriate flanges have been inserted already, the reducers will be connected to the flanges.

 

Examples:

(1), (3) Specification for guideline DN100, (2) DN 300, (4) DN200

(1) Specification for pipeline DN100, (2) DN50


Connect all required reducers for the complete active pipeline automatically

Plant Engineering > New > Pipe parts > Reducer > Connect all

The nominal diameter of the individual part connection and the nominal diameter of the pipeline, respectively guideline c-edge, will automatically be used as search criteria for the reducer. The reducer will be connected in the right direction automatically. All parts which are not part of a pipeline, but which are connected at the beginning or the end of a guideline c-edge will be respected (e.g. nozzle in vessel).

Example:

(1) Specification for pipeline DN100, (2) DN50, (3) nozzle DN200 (does not belong to pipeline)

Pipe Parts (PE)Part Selection - Catalogue or Database (PE)Part Selection: AutoReducer, Part Insertion (PE)

© Copyright 1994-2018, ISD Software und Systeme GmbH
Version 2302 - HiCAD Plant Engineering
Date: 11/07/2019

> Feedback on this topic