Rules for the creation of Feature Variants for Plant Engineering parts
Named isolated points
Designation |
Purpose |
Comment |
Position in coordinate system |
---|---|---|---|
! |
Connecting point |
Fitting point |
in origin (0,0,0) |
2 |
Auxiliary point |
|
X = 0, Y = 0, Z > 0 |
Name |
Description |
Attribute (optional) |
---|---|---|
L |
Distance between points “!“ and “2“ |
LAENGE |
If the variables names given in the Name column are used, you do not need to assign any attributes to them via the Variant Editor. If different variables are required, you need to assign the attributes given in the Attribute column.
VAA files
Use the Variant Editor to enter the suitable part type into the VAA file.
Then, use the Variant Editor to expand the VAA file in such a way that it contains values for the sizes specified here, and that the predefined attribute assignment is entered.
Parameter All dimensions must be specified in millimetres; |
Variable |
Assigned attribute |
---|---|---|
Nominal diameter, Connection “!“ |
N |
NENNWEITE |
|
||
Additionally (only if the corresponding standard uses nominal diameters in inches): |
||
Nominal diameter (inches), Connection “!“ |
NI |
N_INCH |
Nominal diameters in inches need to be entered as decimal values as well (e.g. 1.5 for 1 1/2‘‘). |
If required, the attribute LAENGE need to be assigned to the length variables. (see Variables names above).
For variant synchronization you also need to enter the values for the attributes which are to apply to all sub-types of the variant.
Values must be entered for at least the following attributes:
Attribute |
Description |
|||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
BENENNUNG |
Designation of the part |
|||||||||||||||||||||
COMPONENT_TYPE |
Part type (always = Semi-finished material + Plant Engineering) for HELiOS database only |
|||||||||||||||||||||
NORMBEZEICHNUNG |
Standard designation of the part (identical for all sub-types!) An entry is mandatory, even if the part corresponds to no standard. |
|||||||||||||||||||||
|
|
|||||||||||||||||||||
ANSCHLUSSART |
Connection type for connection “!“ (always flange connection) |
|||||||||||||||||||||
ANSCHLUSSART2 |
Connection type for connection “2“ (always 0) |
|||||||||||||||||||||
Possible values of the attribute ANSCHLUSSART (CONNECTION_TYPE):
The last character (x) provides information about the meaning of the supplement: 0 =No supplement 2 = The supplement consists of connection number, part type, ID, and standard of the part to be connected The prefixed connection number indicates the connection with which the auxiliary part is to be attached to the current connection.
Please also read the information given in the paragraphs Connection type ID with priority information and Connection type ID - List of part standards. |
Handling of nominal diameters in inches in the HELiOS database:
During part data synchronization, nominal diameters in inches will be taken over to the attributes N_INCH, N2_INCH and N3_. The usual character strings for indication of the diameter in inches (e.g. 1 1/2‘‘ instead of 1.5) will be auto-generated in the database for the attributes NPS_INCH, NPS2_INCH und NPS3_INCH.
Rules for the Creation of User-Defined Parts (PE)
© Copyright 1994-2018, ISD Software und Systeme GmbH |