Parts for Air Ducts (PE)

If you want to use parts for air ducts and the current database does not yet contain the required data, the following adjustments are required:

Define attributes

Attribute code:

PARAM_A

Attribute description:

Dimension a for air ducts

Data type:

Float

 

Attribute code:

PARAM_C

Attribute description:

Dimension c for air ducts

Data type:

Float

 

Attribute code:

PARAM_E

Attribute description:

Dimension e for air ducts

Data type:

Float

 

Attribute code:

PARAM_F

Attribute description:

Dimension f for air ducts

Data type:

Float

 

Attribute code:

PARAM_H

Attribute description:

Dimension h for air ducts

Data type:

Float

 

Attribute code:

PARAM_R

Attribute description:

Dimension r for air ducts

Data type:

Float

 

The following assignments apply to the part search via database:

Designation acc. to DIN 24191

 Attribute

a

 PARAM_A

b

 NENNWEITE

c

 PARAM_C

d

 NENNWEITE2

e

 PARAM_E

f

 PARAM_F

h

 PARAM_H

r

 PARAM_R

Classification

If the following classes already exist, they need to be deleted:

Below KLASSENSTRUKTUR (CLASS STRUCTURE), create the Air ducts class (without mask name). Then create the following classes below Air ducts:

Class name

Mask name

Key

Straight pipe (round)

sml_lt_rohr

1030010

Bend, symmetrical (rectangular)

sml_lt_bogensym

2210020

Bend transition (rectangular)

sml_lt_bogenueber

2230020

Angle, symmetrical (rectangular)

sml_lt_winkelsym

2220020

Angle transition (rectangular)

sml_lt_winkelueber

2240020

Duct part (rectangular)

sml_lt_kanalteil

1020020

Offset bend, symmetrical (rectangular)

sml_lt_etagesym

5410021

Offset bend (rectangular)

sml_lt_etageueber

5420021

Base (rectangular)

sml_lt_boden

5220020

Pipe transition, symmetrical (rectangular)

sml_lt_rohruebersym

5610030

Pipe transition, asymmetrical (rectangular)

sml_lt_rohrueberasy

5620031

Transition, symmetrical (rectangular)

sml_lt_uebergangsym

5510020

Transition, asymmetrical (rectangular)

sml_lt_uebergangasy

5520021

Transition nozzle (rectangular)

sml_lt_stutzenueber

5530021

Y-piece(rectangular)

sml_lt_hosenstueck

3210021

T-piece, with offset (rectangular)

sml_lt_tstueckmitvers

3130021

T-piece, without offset (rectangular)

sml_lt_tstueckohnevers

3120020

Other duct parts (rectangular)

sml_lt_sonstiges

5902021

Perform Variant AutoSync